BPR-2 — Application Procedures and Rules for AM Broadcasting Undertakings (sf09211)

Annex A — Sample Sheet: Groundwave Interference Analysis

GROUNDWAVE INTERFERENCE ANALYSIS FOR XXXA, CITY 1, PROVINCE, POWER: 5 kW, FREQ.: 1000 kHz, CLASS B
PROTECTED STATIONSPROTECTED STATION TO PROTECTED POINTINTERFERING STATION TO PROTECTED POINT
CALLFREQ.
(kHz)
CL.PWR
(kW)
LOCATIONPT.CONT
(mV/m)
RADN
(mV/m)
BRG
(deg)
DIST
(km)
PATH
ANALYSIS
RADN
(mV/m)
BRG
(deg)
DIST
(km)
PATH ANALYSIS
(Cond./dist.)
PERM
SIG
(mV/m)
INT
SIG
(mV/m)
XXXB1000B1City 2, Prov/StateA0.5 391 71.5136.78/136.7738.5 230391 6/128.7 2/16.5
10/22.5 8/77
.0250.174
B 0.5 379.7 52.5 135.1 8/135.1 782.1 236.5 381.3 6/143 2/149.6
10/16.1 8/77
.025 0.176
C 0.5 373.3 45 134.3 8/134.3 723.9 239 381.3 6/146.4 2/151
10/27.3 8/72.4
.025 0.0208
D 0.5 368.5 38.5 133.5 8/133.5 727.3 241.5 389.4 6/154 2/112.6
10/49.9 8/72.4
.025 0.0221
E 0.5 362 30 131.9 8/131.9 728.9 243.5 399 8/153 2/115.8
10/54.7 8/75.6
.025 0.0149
XXXC 1000 B 10 City 8, Prov/State A 0.5 1568.8 14.5 232 15/29 
10/203
748.2 165 358.8 6/75.6 2/278.3
10/4.8
.025 0.0163
B 0.5 1562.8 5.5 230 15/32 
10/198
764.3 172.5 354 6/77.2 2/197.9
10/77.2
.025 0.0204
C 0.5 1383.7 353.3 220 15/32 
10/188
778.7 181 358.8 6/48.3 2/181.8
10/53 4/11.3
.025 0.0213
D 0.5 1142.4 343 206 15/37 
10/169
785.2 187.5 360.4 6/53.1 2/173.8
10/175.4
.025 0.0224
E 0.5 828.6 328 186 15/37 
10/149
788.4 191.5 436 6/53.1 1/172.2
10/175.4
.025 0.0122

Annex B — Sample Sheet: Skywave Interence Analyses

SKYWAVE INTERFERENCE ANALYSIS FOR XXXA, CITY 1, PROVINCE
PROTECTED STATIONSINTERFERING STATIONINTERFERENCE (mV/m)

Note: For the band 1605-1705 kHz skywave, studies are based on protecting allotment areas.

* Contributor to the calculated value of Eu

CALLCLPWR (kW)LOCATIONCALLCLPWR
(kW)
LOCATIONDIST
(km)
BRG
(deg)
Θ
(deg)
RADN
(mV/m)
INT
(10%)
EuPROP
RADN
PROP
INT
XXXXB2.5City 2, Prov/StateXXXBB1City 2, Prov/State878.5304.510.4342.74.9   
XXXC B 5 City 3, Prov/State 1227.7 104.5 6.1 555.1 4.55      
XXXD B 1 City 4, Prov/State 1755.4 328 2.3 307.3 0.96      
XXXE B 5 City 5, Prov/State 1108.6 354 7.3 1312.9 13.2* 13.2    
XXXF B 50 City 6, Prov/State 2429.6 48 0 2558.3 3.21      
XXXA B 10 City 1, Prov 1166.5 282.5 7.0 489.9 4.48   371.8 3.4
XXX1 B 50 City 13, Prov/State XXXB B 1 City 2, Prov/State 1327.6 101 5.3 90.1 0.626      
XXXC B 1 City 8, Prov/State 810.9 89.5 16.1 18.5 0.288      
XXXH B .5 City 9, Prov/State 381.3 83 25.9 52.6 1.484* 2.43    
XXXI B 50 City 10, Prov/State 978.3 39 8.9 156.7 1.918*      
XXXJ B 1 City 11, Prov/State 1255 56 6.0 104.1 0.79      
XXXA B 10 City 1, Prov 1041 127 8.0 16.1 0.18   93.3 1.044

Annex C — ITU T04 Electronic Format for MF Sound Broadcasting Service in Region 2 Governed by the RJ81 Agreement

The International Telecommunications Union (ITU) has published guidelines for the submission and notification of electronic notices related to frequency assignments for stations governed by the Regional Agreement for the Medium Frequency Broadcasting Service in Region 2, Rio de Janeiro 1981 (RJ81). This includes Canadian AM stations. Note that since extended or critical hours are not covered by the RJ81 agreement, any relevant details should be provided in the forms listed in Annex 1, Part IV of the Canada/USA Agreement, 1984.

The following is an example of the data format for an electronic notice in ITU T04 format:

<HEAD>

t_adm=CAN

</HEAD>

<NOTICE>

t_notice_type=T04

t_fragment=RJ81

t_action=ADD

t_freq_assgn=1.00

t_long=-0643211

t_lat=+442141

t_site_name=BRIDGEWATER

t_rj81_cls=B

t_ctry=CAN

<OPERATION>

t_op_prd_cde=HJ

t_emi_cls=A3E--

t_pwr_kw=10.000

t_e_rms=917.33

t_bdwdth=10.000

t_ant_type=A

t_e_rms=483.35

t_tran_sys=ANALOG

<TOWER>

t_twr_no=1

t_structure=0

t_hgt_elec=60.000

</TOWER>

</OPERATION>

<OPERATION>

t_op_prd_cde=HN

t_emi_cls=A3E--

t_pwr_kw=10.000

t_bdwdth=10.000

t_ant_type=B

t_e_rms=917.33

t_tran_sys=ANALOG

<TOWER>

t_twr_no=1

t_structure=0

t_fld_ratio=1

t_phase_diff=0

t_spacing=0

t_orient=0

t_hgt_elec=60.000

</TOWER>

<TOWER>

t_twr_no=2

t_structure=0

t_fld_ratio=.51

t_phase_diff=260

t_spacing=90

t_orient=90

t_hgt_elec=60.000

</TOWER>

<TOWER>

t_twr_no=3

t_structure=0

t_fld_ratio=.51

t_phase_diff=100

t_spacing=90

t_orient=270

t_hgt_elec=60.000

</TOWER>

</OPERATION>

</NOTICE>


Annex D — Summary Sheet

Applicant: space to insert text

Account Number:space to insert text

Station: New   Change 

 

Principal Service Location (including province): space to insert text

Station Call Sign: space to insert text

Originating Station (if rebroadcasting): space to insert text

Frequency: space to insert text MHz

Channel Number (extended band):  space to insert text

Class of Station: space to insert text

Different parameters during critical hours? (Y/N)

Site Details: (Provide both day and night site details if they differ. Specifycritical hours parameters if applicable.)
Street Address or Site Name: space to insert text
City: space to insert text
Province or Territory: space to insert text

Antenna Coordinates (WGS84):
N. Lat. space to insert text ° space to insert text ' space to insert text.space to insert text"
W. Long. space to insert text ° space to insert text ' space to insert text.space to insert text"

Transmitter: (Provide both day and night site details if they differ. Specify critical hours parameters if applicable.)

Manufacturer / Model / Certification Number: 
Output Power: space to insert text kW

r.m.s. field strength value of pattern at 1 km: space to insert text 
(Provide both day and night site details if they differ. Specify critical hours parameters if applicable.)

Audio Mode of operation (mono/stereo) space to insert text